XN-1500

For the first time, we have combined our market-leading XN-Series analyser with a brand-new slide maker/stainer in an all-in-one workstation. Should an analysis result lead to a smear, it is performed without manual intervention. The result? Consistent smears with a beautiful cell monolayer that make further microscopic diagnostics as easy and powerful as possible. Add a DI-60, our digital imaging analyser, and microscopic analysis can be performed automatically, too.

Reflex testing occurs within the same loop, and so does the smear preparation when it is needed. Like extended measurements, smears are only initiated if they offer additional diagnostic value. The analysis profile is extended automatically to include smear-making and staining, but you may also order this up front, for instance with known special samples.

Technical Specifications

Measurement principles

WBC DIFF/RET/PLT-F/WPC: Fluorescence Flow Cytometry
RBC/PLT: Hydrodynamically focussed impedance
HGB: Cyanide-free SLS haemoglobin

Aspiration volume

XN:
88 µL in whole blood (WB) mode and body fluid (BF) mode

SP-50:
70 µL for smear preparation in auto mode,
38 µL for smear preparation in manual mode

Throughput

XN:
up to 100 samples/h in whole blood (WB) mode,
up to 40 samples/h in body fluid (BF) mode

SP-50:
up to 30 slides/h in standard mode,
up to 75 slides/h with the optional high-throughput licence

Quality control materialXN Check (three levels) and XN Check BF (two levels)

Parameters

XN-CBC (always with NRBC) & XN-DIFF (always with IG)

Whole Blood

WBC, NRBC%, NRBC#, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MicroR%, MacroR%, PDW, MPV, P-LCR, PCT, NEUT%, NEUT#, LYMPH%, LYMPH#, MONO%, MONO#, EO%, EO#, BASO%, BASO#, IG%, IG#

With RET (optional)

RET%, RET#, IRF, LFR, MFR, HFR, RET-He, RBC-He, Delta-He, HYPO-He%, HYPER-He%, PLT-O

With PLT-F (optional)

PLT-F, IPF, IPF#

With WPC (optional)

Extended Inflammation Parameters licence: NEUT-GI, NEUT-RI, RE-LYMP%, RE-LYMP#, AS-LYMP%, AS-LYMP#

XN Stem Cells licence

HPC%, HPC#

Body Fluids with XN-BF (optional)

WBC-BF, RBC-BF, MN%, MN#, PMN%, PMN#, TC-BF#

 

Contacts
Έχετε κάποια ερώτηση και θέλετε να επικοινωνήσετε με τους ειδικούς μας; Ανυπομονούμε να λάβουμε το ερώτημά σας.

Sysmex Greece

Stournari Street 51

10432 Athens, Greece

www.sysmex.gr

Training

This course is intended for daily or frequent operators of the XN-1500. Whether you're getting started or just want to refresh your knowledge, you will find useful information here.

Sysmex Academy

Ανακαλύψτε περισσότερα

XN-1000

XN-1000

Sysmex’s flagship analyser

Λεπτομέρειες
XN-1000 Pure

XN-1000 Pure

XN-1000 Pure

Λεπτομέρειες
XN-2000

XN-2000

A perfect pair for basic and extended testing

Λεπτομέρειες
Copyright © Sysmex Europe SE. All rights reserved.
Anti‑Bribery Contact Email For any matter related to bribery, integrity, or compliance, you may contact us confidentially at: info@sysmex.gr. All reports are handled with strict confidentiality and without any risk of retaliation.